Error messages / troubleshooting
FAM 25/45/60/75/95
en(us)
Page 149/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
37. Saturation oil >= 90%. Measurement with CS 1xxx not possible!
Cause:
Error-free measurement of contamination is not possible with a
water content
≥
90%. The charge pump of the CS is switched
off.
If you selected an operating mode for which the CS controls
the FAM, then the FAM will automatically jump into a similar
operating mode without control by the CS.
Example: D Filter to => D Filter
Remedy:
The display flashes and shows "Operating mode changed".
It will not be possible to reset this error message until the
relative humidity is <90%.
It will not be possible to select operating modes in which the
CS controls the FAM until the relative humidity is <90%.