FAM Set-up and Connection
FAM 25/45/60/75/95
en(us)
Page 48/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
Filling the rotary vane vacuum pump at the FAM 25
Remove the safety screw for the
plug at the level switch (1).
Remove the plug (2) for the level
switch.
Unscrew the level switch (3) from
the vacuum pump.
Fill up with vacuum pump oil
VE101 through the filling nozzle
(4).
Check the oil level through the
inspection glass (5).
Fill up the vacuum pump oil no
higher than the MAX marking.
We recommend filling up to a level
between the MIN and MAX
markings.
The suction strainer is re-mounted
in reverse order.
1
2
3
4
5
Filling the rotary vane vacuum pump at the FAM 45-95
Remove the screw plug (1).
Fill up with vacuum pump oil
VE101 through the filling nozzle
(1).
Check the oil level through the
inspection glass (2).
Fill up the vacuum pump oil no
higher than the MAX marking.
We recommend filling up to a level
between the MIN and MAX
markings.
The suction strainer is re-mounted
in reverse order.