 802701 - G4  User Guide - 09.2016 - v2.02 

Page 1 of 24

ZIP HydroTap G4 Celsius

 

User Guide

®

• 

Tap Operation..................(Pages 3-5)

• 

LCD Screen & Menu .......(Pages 6-19)

• 

Maintenance.................... (Pages 20-23)

• 

Contact & Details............ (Page 24)

Date of Installation............./........./.........

Affix Model Number Label 

Here

802701 

ARC

CUBE

COMMERCIAL MODELS

Summary of Contents for HydroTap G4 802701

Page 1: ...2 Page 1 of 24 ZIP HydroTap G4 Celsius User Guide Tap Operation Pages 3 5 LCD Screen Menu Pages 6 19 Maintenance Pages 20 23 Contact Details Page 24 Date of Installation Affix Model Number Label Here...

Page 2: ...Page 2 of 24 802701 G4 User Guide 09 2016 v2 02 NOTES...

Page 3: ...ter For your convenience the rotary control is spring loaded so when released will return automatically to the OFF position Rotate for Sparkling water To dispense Sparkling water Model CS175 To dispen...

Page 4: ...s the red mark the temperature is increased The final temperature will be dependant on the temperature of the incoming cold water The spout may be swivelled left or right through 170 for convenience T...

Page 5: ...ctified See section B or call an authorised service man Temperature Warning Light The warning light will flash slowly for 1 sec On and 3 secs OFF whenever the water is not at the temperature set point...

Page 6: ...ts Refer to section B Change Filter External Internal filter needs to be replaced Refer to section C 3LCD Screen Status window Set boiling water temperature Filter usage Date and Time Sleep Mode Icon...

Page 7: ...tallation Filter Flush Filter Reset Reset options Calibration options C Service Password protected D Security Enable Password Set Password Change Password E Communication Remote Monitor Remote Control...

Page 8: ...s Home button to return to the home screen 1 Press System Faults to check the fault information 2 Press button for the previous menu or press Home button to return to the home screen 1 Press Filtert L...

Page 9: ...o purge the gas lines 1 Press the MENU button for main menu 2 Press the Install button 3 Press the Purge CO2 button 4 In the next screen press the START button to commence the purging process 5 Wait f...

Page 10: ...the filter flush has finished press the Stop button to display the main menu OPEN Position CLOSED Position ON OFF 1 Press the MENU button for main menu 2 Press the Install button Turn the stop cock ON...

Page 11: ...ooster 5 Dispense boiling water for a minimum of 30 secs and check the outlet hose from the Booster is warm 6 Otherwise select NO if no Booster is installed This function should only be considered whe...

Page 12: ...a password 1 Press the MENU button for main menu 2 Press the Security button 3 Press Change Password 4 Enter a 4 digit password 5 Lux light level Sensor Calibration All 1 Press MENU button for main me...

Page 13: ...droTap unit F Communication when available The Zip HydroTap G4 allows the user to use wifi to monitor control the product remotely Not yet available G Settings All 3 LCD Screen operation Section G g I...

Page 14: ...circumstances adjustments may be made between 68 100 C It should be noted that a 6 energy saving in standby power can be achieved when the 98 C setting is selected over the 100 C setting Furthermore t...

Page 15: ...is function is to reset the Filter change display after a filter has reached the end of its life refer to Replace Filter Instructions section of this document 1 Press the MENU button for main menu 2 P...

Page 16: ...options as shown in the table below Energy Modes Boiling models In SLEEP MODE the unit will Go to Sleep after a 2hr period of inactivity The Boiling water will gradually drop to either 68 C or room t...

Page 17: ...vidual days for programming Only one ON OFF period is allowed for each day In ON OFF Mode the user may turn the unit ON or OFF at specific times for individual days or alternatively by weekly and or w...

Page 18: ...on 3 Press the Dispense Time button 4 Select the option to change and scroll using the up and down arrow Keys 5 Press HOME to return to the Home screen LCD Screen operation Section G NOTE The Hot Isol...

Page 19: ...in place 9 Fit the bottle in an upright position use the hook and loopsecuring strap 10 Turn the regulator grey knob ON Clockwise and adjust to betweem 2 7 3 0 bar Green zone on dial 11 Check all join...

Page 20: ...ter cartridge replacement and push the new cartridge into the filter head 9 Turn the cartridge a quarter turn to the right until the cartridge comes to complete stop and is locked into position with t...

Page 21: ...side of the under sink unit The screen may be removed for cleaning by sliding it forward This needs to be inspected at least quarterly cleaned and replaced if damaged NOTE For best performance the un...

Page 22: ...the heating element See pages 16 and 17 for Energy Mode options Filter use This icon displays the filter usage remaining from 100 New filter to 0 end of life When it reaches 0 the filter warning light...

Page 23: ...802701 G4 User Guide 09 2016 v2 02 Page 23 of 24 NOTES...

Page 24: ...are pending Head Office Zip Heaters Aust Pty Ltd ABN 46 000 578 727 67 Allingham Street Condell Park NSW 2200 Postal Locked Bag 80 Bankstown 1885 Australia Website www zipindustries com Facsimile 02 9...