Performing Maintenance
FAM 25/45/60/75/95
en(us)
Page 93/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
Cleaning the condensation cooler of the vacuum pump
To perform these tasks, you will need the following tools and equipment:
Compressed
air
VacuCleaner
Bucket (~ 25 liters) or comparable vessel
Hot water 60-65°C
O-rings (1x 67.95 x 2.62, 1x 72.62 x 3.53)
Philips screwdriver, PH#2
Philips screwdriver, PH#3
Flat-bladed screwdriver 0.6x4.5x100
Hexagon screwdriver (wrench) Size 5
To clean the condensation cooler, proceed as follows:
1.
Remove the cover plate.
Remove all of the hoses attached to the
condensation cooler.
Place unambiguous marking on the hoses for
later re-assembly.
2.
Unscrew the condensation cooler and pull it out.
3.
Remove the four front cap screws. Remove the
cap.