Performing Maintenance
FAM 25/45/60/75/95
en(us)
Page 106/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
9. Put the cover on.
Observe correct placement of the
O-ring on the cover while doing so. It
must not be damaged.
10. Fold the 4 screws upward and,
working cross-wise and clockwise,
screw them in with uniform tightness.
11. Close the drain valve.
12. Switch on the FAM at the main switch.
13. Unscrew the air bleed screw (1) in the
filter cover.
Once the filter housing is completely
filled, screw in the air bleed screw
clockwise by hand and tighten it firmly
with an Allen wrench.
14. Check the FAM for any leaks.