Technical Specifications
FAM 25/45/60/75/95
en(us)
Page 35/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
Technical Specifications
The FAM is able to dewater authorized fluids down to a water content of less than
100 ppm and transformer oils down to less than 10 ppm.
As an approximate guideline, the dimensioning of the FluidAqua Mobil can be
defined in accordance with the tank volume.
Tank volume in liters
Filter Size
< 1,500
FAM 5
1,000 – 7,000
FAM 10/15
7,000 – 15,000
FAM 25
15,000 – 25,000
FAM 45
25,000 – 35,000
FAM 60
35,000 – 45,000
FAM 75
> 45,000
FAM 95
Generally speaking, however, it must be taken into account that the design depends
on the application, the fluid and the ambient temperature, the fluid amount and the
water input into the system.
These exercise a great influence over the dewatering performance. It is for that
reason that the specifications can serve only as a starting point.
The dewatering performance is dependent upon:
Dewatering
performance
Water content
Fluid temperature
Detergent additives
Volumetric flow of the FAM