Performing Maintenance
FAM 25/45/60/75/95
en(us)
Page 113/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
12. Insert the filter element holding plate
[B]
.
Fasten on the external filter elements. The
middle filter elements do not require any further
fastening.
Screw on all of the star grips
[A]
gently by
hand.
[A]
[B]
13. Clean the sealing surface on the housing.
Check the O-ring on the cover for damage and
replace it if necessary.
Moisten the O-ring with the operating medium.
14. Clean the sealing surface on the cover.
Place the cover on the filter housing and center
it.
15. Screw on the tensioning clamp with a 13 mm
wrench and tighten it with a steady torque of
≥
8 Nm and
≤
20 Nm. Screw on the lock nut and
tighten it.
16. Fill the filter housing. Vent the filter housing
using the ventilation plug in the cover until oil
emerges.
Do not unscrew the ventilation plug completely
— it has ventilation slots.
17. The filter element change on the fluid filter is
now complete.