Performing Maintenance
FAM 25/45/60/75/95
en(us)
Page 116/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
Testing the Float Switch in the Oil Pan
Proceed as follows to test the float switch in the oil pan:
1.
Use your fingers to raise the float switch in the
oil pan.
2.
The unit must switch off and the fault
message "Pan overfilled" must appear in
display of the control panel.
3.
Release the float switch and acknowledge the
fault message by pressing the F3 key.
4.
The unit continues to operate -> You have
tested the function of the float switch
positively.
5.
If the unit does not switch off after the lifting of
the float switch and no fault message
appears, contact the HYDAC Service.