Possible Applications of the FAM
FAM 25/45/60/75/95
en(us)
Page 38/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
Possible Applications of the FAM
Cleaning in Bypass Flow
The FAM is connected with suction and pressure lines to the tank and cleans the
medium to be found in it in constant bypass flow.
Purifying and transferring by pumping
The FAM is connected to the contaminated oil tank with the suction hose and
pumps the fluid into the tank for the purified oil while cleaning it at the same time.
(A) = Waste oil tank
(B) = Pure oil tank
The fill level of clean-oil tank is to be monitored constantly during this process to
prevent overfilling.
You achieve permanently better levels of purity by operating the system
continuously in bypass flow.