Resolving errors/Eliminating errors
FAM 5
en-US
Page 92 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
05 Vacuum column sensor
Trigger for the
message:
Two switch points on the float switch of the vacuum
column were reached at the same time, which are
conflictive or do not follow each other logically.
The unit stops immediately.
Remedy:
Perform the following steps:
S
te
p
Description
1.
Message:
05 Vacuum column sensor
2.
Switch off the unit at the main switch.
3.
Check that the level switch of the vacuum column works.
4.
->a. Level switch is OK.
-> proceed to Step 5.
->b. Level switch is not OK.
-> proceed to Step 7.
5.
Check the plug to the level switch.
Check the cable from the level switch to the control cabinet and
in the control cabinet to the PLC.
6.
->a. The cable and plug are OK.
-> proceed to Step 9.
->b. The cable and plug are not OK. -> proceed to Step 8.
7.
Replace the level switch.
-> proceed to Step 10.
8.
Replace the damaged parts.
-> proceed to Step 10.
9.
The PLC is defective -> contact the HYDAC Service Department.
10.
The error is repaired.