Maintenance
FAM 5
en-US
Page 122 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
Cleaning the suction strainer
NOTICE
Operation without a suction strainer
The pump will be destroyed
►
The unit may not be operated without the suction strainer.
►
Clean the suction screen regularly.
Screw wrench
= 32 mm
To protect the pump from coarse contamination particles and other foreign
bodies, a dirt trap with a strainer insert is fitted at the pump inlet.
Clean the suction strainer at regular intervals.
To install / dismount the suction screen, proceed as follows:
1
2
3
1. Unscrew the screw plug (1) counterclockwise using an open-jaw
wrench.
2. Remove the suction screen (3).
3. To clean the suction screen, wash it out with solvent and then dry it
using compressed air.
4. Check the suction screen (3) and sealing ring (2) on the screw plug for
damage. Replace it if necessary.
5. Install the sieve insert (3).
6. Turn the screw plug (1) clockwise manually.
Tighten the screw plug (1) using the open-jaw wrench.
7. After commissioning, check the suction strainer fittings for leaks.