26 Heater thermostat
Trigger for the
message:
The safety thermostat trips during operating mode with
heater. The unit switches to the cool-down and reset
phase, then switches off.
This error notification can be connected with a preceding
error notification and with the immediate switch-off of the
unit that takes place as a result.
Notification only displays for FAM-5-x-x-x-xx-H-x-x-.
Remedy:
If this is not an inherited error, then proceed as follows:
S
te
p
Description
1.
Message:
26. Heater thermostat
2.
Switch off the unit at the main switch.
3.
Let the unit and heater cool down. The mechanism is tripped by a
bi-metal. This bi-metal must first cool down in order to recover.
4.
Pull the setting switch of the heater up and off. And remove the
two covering stoppers of the screw holes.
5.
Unscrew and remove the two
screws (
= 20).
6.
Lift off the cover upwards.
7.
Press the pin/lever (T) on the
safety thermostat with a small
screwdriver.