Resolving errors/Eliminating errors
FAM 5
en-US
Page 93 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
12 measured value AS temp / 13 measured value AS %S
Trigger for the
message:
No valid signal received from sensors.
12 measured value AS temp: The unit continues to
operate.
13 measured value AS %S: The unit switches to the
follow-up phase and switches off.
Remedy:
Perform the following steps:
S
te
p
Description
1.
Message:
12 measured value AS temp
13 measured value AS %S
2.
Switch the unit off at the main switch and unplug the power
connector.
3
Check the cables and plugs of the corresponding sensor up to
the PLC.
4.
->a. The cable and plug are OK.
-> proceed to Step 5.
->b. The cable and plug are not
OK.
-> proceed to Step 9.
5.
Check / replace the sensor
6.
Plug the power plug into the power outlet.
Switch on the FAM at the main switch and start operation by
pressing the F1 key.
7.
->a. The fault is repeated.
-> proceed to Step 8.
->b. The fault is not repeated.
-> proceed to Step 13.
8.
The PLC is faulty.
-> proceed to Step 12.
9.
Replace the cable and/or the plug.
10.
Plug the power plug into the power outlet.
Switch the unit on using the main switch and start operation by
pressing the F1 key.
11.
->a. The fault is repeated.
-> proceed to Step 5.
->b. The fault is not repeated.
-> proceed to Step 13.
12.
Contact the HYDAC Service Department.
13.
The fault is repaired.