Selecting the operating mode
FAM 5
en-US
Page 68 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
Emptying the vacuum column
Description
Vacuum
column MIN
YES = Vacuum column level switch
≤ MIN
NO = Vacuum column level switch > MIN
Reset time
Reset time remaining after fill level "Min" (the min. level in
the vacuum column) is reached.
EMPTY
After pressing the function key F3 "START", the oil is
pumped out of the vacuum column until fill level "Min" is
reached in the vacuum column. The unit then runs for a
"reset time" of 10 seconds.
The vacuum column cannot be completely emptied in
manual mode since part of the pumped oil returns to the
vacuum column via the flow divider.
MANUAL
HOME
Vacuum column
MIN
1/2
EMPTY
START STOP