Unit setup and connection
FAM 5
en-US
Page 40 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
Connecting the inlet (IN)
The maximum permitted pressure P
e perm
at the inlet to the FAM can be found
in the technical data.
Use a negative pressure-resistant, flexible hose or a pipe for the suction-side
connection.
Make sure that the cross-section of the connection lines is at least as large
as the cross-section of the connection threads.
The tank connection should be set up in such a way that it is always lower
than the level of the oil in the tank.
NOTICE
Contamination too high
The FAM will be damaged
►
Do not prime directly at the bottom of the tank.
►
Do not prime in the sump.
►
Never prime without a built-in suction screen.
The greatest contamination is found on the bottom of the tank.
All impurities and other particles are deposited on the bottom of
the tank. All impurities and other particles are deposited on the
bottom of the tank.
Connecting the outlet (OUT)
The maximum permitted pressure at the outlet P
a perm
can be found in the
technical data.
NOTICE
Connection OUT closed off
The FAM switches over to error mode
►
Check to be sure that all of the locking fixtures at the outlet are in
"open" position each time before commissioning.
In order to prevent air accumulation in the fluid, ensure that the
return hose with lance is always below the oil level when in
operation.