11. Slide the tensioning clamp (1) from the bottom over
the filter bowl to the top over the bead on the filter
bowl / filter head.
Tighten the tension clamp clockwise with an Allen key
= 6 mm.
The tightening torque is 5 Nm.
12. Check that the drain plug on the filter bowl is secure.
13. The filter element change is now complete.
Bleed the filter housing as described on page 55.
After commissioning, check the filtration unit for
leaks.