Checking the directionof rotation of the electric motor
Check the direction of rotation of the motor by switching it on briefly (jog
mode). The FAM requires a clockwise rotating field of the connection socket.
NOTICE
Incorrect phase sequence / rotation direction of the electric motor
The pumps will be destroyed.
►
In jog mode, check the direction of rotation of the electric motors. A
rotation direction arrow on the fan cover of the electric motor depicts
the correct direction of rotation.
If rotation occurs in the opposite
direction, rotate the phases using the
phase inverter in the connection plug.
For units without a plug, both the
phases must be switched on the
terminal strip X0 (for example L1 and
L2)