Resolving errors/Eliminating errors
FAM 5
en-US
Page 88 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
No. Function
Details
1
Display of the error number(s) of the error(s)
currently pending.
Example in window above:
#33 = Vacuum column alarm
#34 = Dry tray full.
NOTICE: Errors "12/13", "18/19" and "26/28" are
always displayed together. In these cases, it must
be determined which error has actually occurred.
Page 85 and
starting on page
90
2
Brief description of error
Page 85 and
starting on page
90
3
Error code containing all errors. The displayed
code corresponds to the sum of the codes for
each active error. The code displays as long as
the error is active.
Example in window above: "+518"
#33 = Vacuum column alarm, code = 4
#34 = Dry tray full, code = 2
#28 = Heater motor protection switch, code = 512
Overall code = 4 + 2 + 512 = 518
Page 85
No more than three preset error notifications are displayed per window. This
is why the errors are shown in multiple windows. The error code is displayed
across all windows.
Use the down
▼ and up ▲ arrow keys to switch between the windows.
Proceed as follows to restart the power unit:
ERROR
RESET with ENTER
23 Filter clogged
33 Vacuum column alarm
34 Drip tray full
NEXT ERRORS
▼▲
# 33
# 34
1
2
+518