Maintenance
FAM 5
en-US
Page 114 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
4.
Fill the vacuum pump with the vacuum
pump oil via the filler neck (a).
5.
Check the oil level through the sight glass
(d).
For trouble-free operation, we recommend
a fill level centered between the MIN and
MAX markings.
6.
Insert the level sensor into the vacuum
pump from above. To facilitate installation,
lift the lower float upwards.
Screw the level switch (m) with a screw
wrench
= 24 mm turning clockwise in
the vacuum pump and tighten it.
7.
Insert the plug (l) into the level switch and
secure it by tightening the threaded
coupling (k).
8.
The vacuum pump filling is complete.