NOTICE
The OT terminal may rotate and result in device damage. Make sure that it is independent of
the adjacent metal mechanical part or other terminals.
Technical Specifications
shows the technical specifications of the PGND cable.
Table A-1
Technical specifications of the PGND cable
Name
Description
PGND cable
Terminal
Naked Crimping Terminal,OT,6mm
2
,M6,Tin
Plating,Insulated Ring Terminal,12~10AWG,yellow
Terminal
Naked Crimping Terminal,OT,6mm
2
,M4,Tin
Plating,Insulated Ring Terminal,12~10AWG,yellow
Cable
Power Cable,450/750V,H07Z-K UL3386,6mm
2
,Yellow/
Green,Low Smoke Zero Halogen Cable
A.1.2 AC Power Cables
This section describes the AC power cables of the USG that uses the AC power supply. Learn
about the structure and specifications of the AC power cables and the local standards before
you purchase any for the USG.
Use a single-phase 3-line electrical outlet that has been properly grounded.
NOTICE
Make sure that the power system of the building has been grounded before you connect the
USG with AC power cables.
Structure and Appearance
The USG provides both the European-standard and North American-standard AC power
cables.
list the reference specifications. You can select the desired power cables
based on your site conditions.