DANGER
Do not connect or disconnect the power cables when the USG is powered on.
Procedure
Step 1
Ensure that the PGND cable is properly grounded.
Step 2
Ensure that the USG is powered off.
Step 3
Connect the power cables to both DC power supply modules one after the other.
NOTICE
l
Note the labels on the DC power cables to prevent connection mistakes.
l
When two power modules are used, connect them to different power sources to improve
availability.
1.
Connect the power plug of the DC power cable to the DC power supply module.
2.
Connect the other ends of the DC power cables to the output terminals on the power
supply device.
Figure 3-74
Connecting the DC power cables
Secospace USG6000
FAN STATUS
FAN
9 PWR 10 PWR
11
F
A
N
12
SPU
SPU
13
RUN
ALM
SPUB
PWR350D
PWR
STATUS
NEG(-)
RTN(+)
-48V~-60V;9.6A
OFF
ON
PWR350D
PWR
STATUS
NEG(-)
RTN(+)
-48V~-60V;9.6A
OFF
ON
MGMT
CONSOLE
0
HDD0
HDD1
RST
EN
EN
SYS ALM MODE
SPUA
NEG(-) RTN(+)
NEG(-) RTN(+)
PWR STATUS
NEG(-)
RTN(+)
-48V~-60V;9.6A
OFF
ON
NEG(-)
RT
N(+)
DC power cable
DC power cable
Terminals must be assembled
by the customer.
The USG provides cord end terminals and OT bare crimp terminals. You can use them
based on the actual condition, including striping the cable, assembling a terminal, and
crimping the cable.
HUAWEI USG6000 Series
Hardware Guide
3 Hardware Installation
Issue 08 (2017-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
331