Procedure
Step 1
Loosen and remove the screw of the ground terminal on the USG rear panel.
Step 2
Align the M4 end of the PGND cable with the screw hole of the ground terminal and tighten
the screw.
Step 3
Connect the M6 end of the PGND cable to the ground terminal of the cabinet, workbench, or
wall.
Figure 3-30
Connecting a PGND cable
Secospace USG6000
0
2
4
6
1
3
5
7
RST
12V ; 3A
CONSOLE
XXXXXXXXXXXXXXXXXXXXXXXXXXX
Cabinet ground point
Workbench ground point
Wall ground point
PGND cable
1
2
3
----End
Follow-up Procedure
Verify the following after the cabling is complete:
l
The PGND cable is securely connected to the ground terminal.
l
The electrical resistance between the ground terminal and ground point is less than 5
ohm on a multimeter.
3.3.3 Connecting a Console Cable
After connecting a PC to the console port of a USG6310/6320 with a console cable, you can
use the terminal emulation program on the PC to access the command configuration interface
of the USG6310/6320.
Context
Before connecting a console cable, perform the following operations:
l
Check preparations.
HUAWEI USG6000 Series
Hardware Guide
3 Hardware Installation
Issue 08 (2017-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
278