Figure 3-73
Connecting the AC power cable
FAN STATUS
FAN
9 PWR 10 PWR
11
F
A
N
12
SPU
SPU
13
RUN
ALM
SPUB
~100-240V;50/60Hz,10A
PAC-700WA-L
STATUS
~100-240V;50/60Hz,10A
PAC-700WA-L
STATUS
MGMT
CONSOLE
0
HDD0
HDD1
RST
EN
EN
SYS ALM MODE
SPUA
AC power supply B
~100-240V;50/60Hz,10A
1
2
3
AC power cable
AC power cable
AC power supply A
----End
Follow-up Procedure
Verify the following after the connection is complete:
l
The power cable is firmly connected to the power supply socket.
l
If multiple USGs are deployed, the power cables of each USG are correctly labeled for
distinction.
3.5.8.2 Connecting DC Power Cables
In standard configuration, the USG6660/6670/6680 has two DC power supply modules. Each
module requires a PGND cable, an NEG DC power cable, and an RTN DC power cable. This
section describes how to connect power cables to the two DC supply modules.
Context
Before connecting power cables, ensure that the DC power supply in the equipment room
meets the input requirements of the USG.
HUAWEI USG6000 Series
Hardware Guide
3 Hardware Installation
Issue 08 (2017-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
330