Name
Description
0 to 7 (RJ45)
8 10/100/1000M autosensing Ethernet electrical ports, numbered from
GigabitEthernet 0/0/0 to GigabitEthernet 0/0/7.
GigabitEthernet 0/0/0 is an inband management port and its default IP
address is 192.168.0.1. After this port is connected to your PC through
network cables, you can log in to the device using Telnet, STelnet, or
web UI to configure or manage the device.
RST button
To restart the device, press the RST button. Ensure that the running
configuration is saved before pressing the RST button.
The RST button can also be used to restore the default settings. To do
so, press and hold down the RST button and power on the device. Three
to five seconds later, when the SYS and ALM indicators on the front
panel are both blinking, release the RST button.
Protective
ground terminal
The M4 OT terminal connects the PGND cable to the ground point of
the cabinet, workbench, or wall, or the ground bar in an equipment
room.
Power
receptacle
Connects to the 4-pin plug of the power adapter.
Clip hole
The hole is used to install the power cable clip, which is used to bind
and fix the power cable.
2.1.6.4 Power Supply System
The USG6310/6320 does not have a built-in power module and requires an external 36W
power adapter.
36W Power Adapter
The 36W power adapter converts AC power to DC power for the device.
illustrates the appearance of the power adapter.
Figure 2-24
Appearance of the 36W power adapter