Figure 4-21
Installing the power module
(USG6306/6308/6330/6350/6360/6370/6380/6390/6390E/
6507/6530/6550/6570/6620/6630)
SM-HDD-SAS300G-B
Secospace USG6000
4 HDD
5 PWR
6 PWR
INPUT
OUTPUT
ON
OFF
~100-240V
;50/60Hz;2.5A
2
INPUT
OUTPUT
ON
OFF
~100-240V
;50/60Hz;2.5A
INPUT
OUTPUT
ON
OFF
~100-240V
;50/60Hz;2.5A
Secospace USG6000
4 HDD
5 PWR
6 PWR
Secospace USG6000
4 HDD
5 PWR
6 PWR
INPUT
OUTPUT
ON
OFF
~100-240V
;50/60Hz;2.5A
INPUT
OUTPUT
ON
OFF
~100-240V
;50/60Hz;2.5A
1
6.
Connect the power cable to the socket on the new power module. For details, see
.
7.
Switch on the power supply device. If the STATUS indictor on the new power module of
the USG is steady green, the power module works properly.
----End
Replacing the Power Module (USG6650/6660/6670/6680)
Step 1
Determine the location of the power module to be replaced and attach a replacement label on
the panel to identify the power module.
Step 2
Disconnect the power supply device from the power module to be replaced.
Step 3
Wear an ESD wrist strap.
Step 4
Remove the power cable connected to the power module.
Refer to the following instructions to remove the power cables:
l
To remove the AC power cable (USG6650/6660/6670/6680):
a.
Press the baffle on the cable retention clip and remove the cable retention clip from
the AC power cable.
b.
Pull out the power cable from the socket on the power module.
l
To remove the DC power cable (USG6660/6670/6680):
a.
Press the red cable retention clips on both sides of the power plug and slide them
outside to separate the cable retention clips from the power socket.
HUAWEI USG6000 Series
Hardware Guide
4 Maintaining the Hardware
Issue 08 (2017-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
360