Procedure
Step 1
Loosen and remove the screw of the ground terminal on the USG rear panel.
Step 2
Align the M4 end of the PGND cable with the screw hole of the ground terminal and tighten
the screw.
Step 3
Connect the M6 end of the PGND cable to the ground terminal of the cabinet, workbench, or
wall.
Figure 3-10
Connecting a PGND cable
1
2
3
Secospace USG6000
0
2
1
3
4
6
5
7
RST
micro SD
12V ; 2A
CONSOLE
LTE DIV
WiFi 0
LTE MAIN
WiFi 1
XXXXXXXXXXXXXXXXXXXXXXXXXXX
Cabinet ground point
Workbench ground point
Wall ground point
PGND cable
----End
Follow-up Procedure
Verify the following after the cabling is complete:
l
The PGND cable is securely connected to the ground terminal.
l
The electrical resistance between the ground terminal and ground point is less than 5
ohm on a multimeter.
3.2.3 Installing a Micro SD Card
This section describes how to install a micro SD card for the first time to avoid damages.
Context
Instruments required:
l
Phillips screwdriver
l
ESD wrist strap
HUAWEI USG6000 Series
Hardware Guide
3 Hardware Installation
Issue 08 (2017-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.