FortiGate-5050 Chassis Guide

01-30000-87211-20090106

1

2

2

3

4

5

ShMC

1

ShMC

POWER

Hot Swap
Status

Alarm

Minor

Console

Ethernet

Alarm

Reset

Critical

Major

MANAGEMENT

SYSTEM

E1

ZRE

LED MODE

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

E2

OK

CLK

INT

EXT

FL

T

HOT SW

AP

RESET

FL

T

CONSOLE

E T H O

R S 2 3 2

Z R E 0

Z R E 1

Z R E 2

MANAGEMENT

SYSTEM

E1

ZRE

LED MODE

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

E2

OK

CLK

INT

EXT

FL

T

HOT SW

AP

RESET

FL

T

CONSOLE

E T H O

R S 2 3 2

Z R E 0

Z R E 1

Z R E 2

PWR

STA IPM

CONSOLE

USB

1

2

3

4

5

6

7

8

ACC

PWR

STA IPM

CONSOLE

USB

1

2

3

4

5

6

7

8

ACC

PWR

STA IPM

CONSOLE

USB

1

2

3

4

5

6

7

8

ACC

A detailed guide to the FortiGate-5050 chassis. This 

FortiGate-5050 Chassis Guide

 describes FortiGate-5050 

hardware features, how to install the FortiGate-5050 chassis, and how to install FortiGate-5000 boards in the chassis.

The most recent versions of this and all FortiGate-5000 series documents are available from the 

FortiGate-5000

 page 

of the 

Fortinet Technical Documentation

 web site (

http://docs.forticare.com

).

Visit 

http://support.fortinet.com

 to register your FortiGate-5050 chassis. By registering you can receive product 

updates, technical support, and FortiGuard services.

FortiGate-5050

Chassis Guide

Содержание FortiGate 5050

Страница 1: ... 2 3 4 5 6 7 8 ACC PWR STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 ACC PWR STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 ACC A detailed guide to the FortiGate 5050 chassis This FortiGate 5050 Chassis Guide describes FortiGate 5050 hardware features how to install the FortiGate 5050 chassis and how to install FortiGate 5000 boards in the chassis The most recent versions of this and all FortiGate 5000 series document...

Страница 2: ... strap and attaching it to an available ESD connector such as the ESD sockets provided on FortiGate 5000 series chassis Make sure all FortiGate 5000 series components have reliable grounding Fortinet recommends direct connections to the building ground If you install a FortiGate 5000 series component in a closed or multi unit rack assembly the operating ambient temperature of the rack environment ...

Страница 3: ...ssis to data center ground 14 Connecting the FortiGate 5050 chassis to AC power using the FortiGate 5053 power converter tray 15 FortiGate 5053 power converter tray front and back panel 15 Selecting the power supplies and power converter trays that you need for your FortiGate 5050 configuration 17 Connecting a FortiGate 5050 chassis to the FortiGate 5053 power converter tray 20 Turning on FortiGat...

Страница 4: ...Contents FortiGate 5050 Chassis Guide 4 01 30000 87211 20090106 http docs fortinet com Feedback ...

Страница 5: ...e channels You can mix and match any combination of FortiGate 5000 series boards in the FortiGate 5050 chassis For example you could install two FortiGate 5005FA2 boards two FortiGate 5001SX boards and one FortiGate 5001FA2 board You can also install FortiController 5208 and FortiGate 5005FA2 boards in a FortiGate 5050 chassis to create a FortiGate 5005 DIST security system Some of the boards inst...

Страница 6: ... the FortiGate 5000 series boards installed in the FortiGate 5050 chassis Each power input connector includes a 24 Amp circuit breaker that also functions as an on off switch for the power input connector If you require redundant power you should connect both power input connectors to DC power If redundant power is not required you should connect power input connector A to DC power When operating ...

Страница 7: ...for FortiGate 5000 RTM modules such as the FortiGate RTM XB2 module When the FortiGate 5050 chassis is shipped these slots are covered by RTM slot filler panels Physical description of the FortiGate 5050 chassis The FortiGate 5050 chassis is a 5U chassis that can be installed in a standard 19 inch rack Table 1 describes the physical characteristics of the FortiGate 5050 chassis 5 4 3 2 1 48V to 58...

Страница 8: ...ED State Description Critical Major Minor Green Normal operation Red Indicate the level of alarm critical major or minor Hot Swap Blue LED is on when ready to be hot swapped Status Green Normal operation Ethernet port Yellow Port is not forwarding packets Green Blinking LED indicates network traffic Off No link Table 3 FortiGate 5050 shelf manager connections Connector Type Speed Protocol Descript...

Страница 9: ...nsole adapter FGSMC ADPTR 1 You cannot connect a standard null modem console cable to the shelf manager console port Figure 4 Connecting to the shelf manager console port To connect to the shelf manager CLI using the shelf manager console port 1 Connect a standard CAT5 RJ 45 Ethernet cable to the shelf manager Console port 2 Connect the other end of the Ethernet cable to the SMC side of the Fortin...

Страница 10: ...r the following Linux command to add a password for the root account passwd 2 Enter and confirm a new password for the root account The password should be between 5 and 8 characters long and should include a combination of upper and lower case letters and numbers You can use the passwd command to change the root account password at any time You can also use the passwd command to remove the root ac...

Страница 11: ...e critical major and minor alarms The alarm LED reset button RESET on the shelf alarm panel activates the Alarm Cutoff ACO state When ACO is activated the active alarm LED blinks and all of the alarm relays are deactivated Shelf manager telco alarms The shelf manager telco alarm interface relay circuits are capable of carrying 60 VDC or 1 A with a max rating of 30 VA The shelf manager accepts time...

Страница 12: ...l chassis cooling and can signal alarms if the chassis encounters problems All FortiGate 5000 boards installed in the chassis communicate with the shelf managers The FortiGate 5050 shelf managers are factory installed In most cases users do not have to install or configure the shelf managers Each shelf manager has one ethernet interface ETH 0 and ETH 1 You can connect to ETH 0 from the shelf manag...

Страница 13: ...etworking or telecom equipment The FortiGate 5050 chassis are designed to be connected directly to this DC power system In this document data center DC power refers to a 48VDC power system that is already available at the location at which the FortiGate 5050 chassis is being installed Connecting the FortiGate 5050 chassis to data center DC power and data center ground Connect the FortiGate 5050 ch...

Страница 14: ...ion plate 3 Insert the black 48V and red RTN wires through the power wire fixture see Figure 6 4 Connect the black 48V power wire from the data center DC power source to the terminal on the FortiGate 5050 power input connector labelled DC in 5 Connect the red RTN return wire from data center RTN to the terminal on the FortiGate 5050 power input connector labelled RTN 6 Make sure the power wires ar...

Страница 15: ...g the FortiGate 5053 power converter tray If data center DC power is not available you can use the FortiGate 5053 power converter tray with FortiGate 5020 5050 power supplies shown in Figure 8 to convert AC power to DC power The FortiGate 5053 power converter tray and the power supplies are not supplied with the FortiGate 5050 chassis and must be purchased separately FortiGate 5020 5050 power supp...

Страница 16: ...ts AC power directly to a FortiGate 5020 5050 power supply The FortiGate 5053 can contain 1 2 or 3 FortiGate 5020 5050 power supplies depending on your requirements You should only connect AC power to the power supplies that are installed Table 5 FortiGate 5020 5050 power supply LEDs LED State Description AC Power Green The power supply is connected to AC power Off The power supply is not receivin...

Страница 17: ...a total of 1600W 2 x 800W of power The third power supply is the redundant backup The maximum power output for a FortiGate 5053 power converter tray with FortiGate 5020 5050 power supplies is 1600W which can be achieved with two FortiGate 5020 5050 power supplies If you need 1600W of power and power supply redundancy you can add a third FortiGate 5020 5050 power supply Individual power requirement...

Страница 18: ...ate 5050 power input connector Slot 1 Slot 2 Slot 3 1 FortiGate 5053 power convertor tray 2 FortiGate 5020 5050 power supplies 2 x 800W 1600W 1 FortiGate 5050 chassis 1 2 2 3 4 5 ShMC 1 ShMC POWER Hot Swap Status Alarm Minor Console Ethernet Alarm Reset Critical Major MANAGEMENT SYSTEM E1 ZRE LED MODE 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 E2 OK CLK INT EXT FLT HOT SWAP RESET FLT CONSOLE E T H O R ...

Страница 19: ...3 2 1 0 E2 OK CLK INT EXT FLT HOT SWAP RESET FLT CONSOLE E T H O R S 2 3 2 Z R E 0 Z R E 1 Z R E 2 PWR STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 ACC PWR STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 ACC PWR STA IPM CONSOLE USB 1 2 3 4 5 6 7 8 ACC Slot 1 Slot 2 Slot 3 2 FortiGate 5053 power convertor trays 1 FortiGate 5050 chassis 2 x 800W 1600W 2 1 redundancy 2 x 800W 1600W 2 1 redundancy 6 FortiGate 5020 5050 po...

Страница 20: ...ewdriver An electrostatic discharge ESD preventive wrist or ankle strap with connection cord One black AWG 14 stranded wire with terminal lugs attached and labelled 48V One red AWG 14 stranded wire with terminal lugs attached and labelled RTN A FortiGate 5053 power converter tray containing two or three FortiGate 5020 5050 power supplies and mounted in a rack near the FortiGate 5050 chassis 1 Atta...

Страница 21: ...are installed in the FortiGate 5053 to AC power For example if your FortiGate 5053 includes two FortiGate 5020 5050 power supplies the power supplies will be installed in slots 1 and 2 In this case you should only connect AC in connectors 1 and 2 to AC power If your FortiGate 5053 power converter tray contains three power supples connect all three AC in connectors to AC power The photograph in Fig...

Страница 22: ... see Figure 8 on page 16 When the FortiGate 5053 power converter is operating normally both of the FortiGate 5020 5050 power supply LEDs should be lit for each connected power supply If you are using data center DC power turn own the power to the chassis according to the requirements of your data center DC power system Once the FortiGate 5050 chassis is connected to DC power you can turn on power ...

Страница 23: ...turer s maximum rated ambient temperature Air flow For rack installation make sure that the amount of air flow required for safe operation of the FortiGate 5050 chassis is not compromised Inserting 5000 series boards into a FortiGate 5050 chassis You can insert FortiGate 5000 series and FortiSwitch boards into the FortiGate 5050 chassis Arrange the boards in slots as required for your configuratio...

Страница 24: ...tch 5003A and 5003 boards installed in a FortiGate 5050 chassis in slot 1 or slot 2 provide base backplane switching for all of the FortiGate 5000 series boards installed in chassis slots 3 and above Base backplane switching is usually used for HA heartbeat communication between FortiGate 5000 series boards in HA clusters For complete information about using the FortiSwitch 5003A and 5003 for back...

Страница 25: ...s is available from the Fortinet Knowledge Center The knowledge center contains troubleshooting and how to articles FAQs technical notes and more Visit the Fortinet Knowledge Center at http kc forticare com Comments on Fortinet technical documentation Please send information about any errors or omissions in this document or any Fortinet technical documentation to techdoc fortinet com Customer serv...

Страница 26: ...s Fortinet FortiGate and FortiGuard are registered trademarks and Dynamic Threat Prevention System DTPS APSecure FortiASIC FortiBIOS FortiBridge FortiClient FortiGate FortiGate Unified Threat Management System FortiGuard Antispam FortiGuard Antivirus FortiGuard Intrusion FortiGuard Web FortiLog FortiAnalyzer FortiManager FortiOS FortiPartner FortiProtect FortiReporter FortiResponse FortiShield and...

Отзывы: