User Manual
U-SYS IAD108 Integrated Access Device
Chapter 7 Maintaining System
7-50
V.
Query by Alarm Class
Command:
show alarm record alarmclass
class
[
startnum
number
]
You can use this command to query alarms by alarm class.
The meanings of the parameters in the command are listed in
Table 7-14.
Table 7-14
Parameters of command
Item Description
Class
Alarm class. There are three classes: event alarm, fault alarm and
recovery alarm. It is only necessary to input the English word
indicating the corresponding class directly.
startnum
The alarm number from which the display starts, the value range is
1–1000. In the Command Line Interface (CLI), you can start the
display from 1, or from a designated
startnum
.
number
Maximum number of alarm records after the
startnum
that can be
displayed in one time. It is an optional parameter, ranging 1–1000.
VI.
Query by Alarm Generation Time
Command:
show alarm record alarmtime
datebegin
timebegin dateend timeend
[
startnum number
]
You can use this command to query the alarms generated within
a certain time segment.
The meanings of the parameters in the command are listed in
Table 7-15.