User Manual
U-SYS IAD108 Integrated Access Device
Chapter 5 Advanced
Configuration
5-23
name value
1: It controls whether the current calls are held when
the communication between the MGC and the MG is
interrupted.
0: yes; 1: no.
2: It controls whether the calls are switched to the
standby MGC when the communication between the
MGC and the MG is interrupted.
The value of 0 indicates
yes; 1 no, that is, the MG
can only register on the
active MGC.
3: It controls whether to stop sending the heartbeat
message between the MGC and the MG.
The value of 0 indicates
yes; 1 no.
4: It is the heartbeat duration.
It is in the unit of seconds,
ranging 0–65,535
seconds.
5: It controls whether the wildcard is used at
registration.
0: yes; 1: no.
6: Whether send long-duration call NTFY to MGC.
This parameter is used when the IAD108 networks
with O company’s softswitch, because this softswitch
cannot recognize the NTFY.
0: no; 1: yes.
Example:
Hold the current calls when the communication between the MGC
and the MG is interrupted.
IAD2000(config)#
mg software-parameter 1 0
IAD2000(config)#