User Manual
U-SYS IAD108 Integrated Access Device
Chapter 4 Configuring Data
4-48
Table 4-17
Parameter of the commands
Item Description
portid
Port number
spcname
Name of an SPC in a character string, the length is between 1 to
8 characters.
remote-ip
IP address of remote MG
local-portt
Local Real-time Transport Protocol (RTP) port number, used to
identify different voice channels. Its value ranges [50000,
50124], and must be a multiple of 4. When adding an IP SPC,
the DSP parameters at both ends must be configured
consistently. For example, if IAD1 uses No. 50000 channel,
IAD2 uses No. 50004 channel, you should configure
local-port
/re
mote-port
on IAD1 as 50000/50004, and
50004/50000 on IAD2.
re
mote-port
Remote Real-time Transport Protocol (RTP) port number,
ranging 0–65535.
connectid
Index of an SPC
fromid
Start index of an SPC
endid
End index of an SPC. In you do not input the
endid
, the last
index will be taken by default.