Professional humidity switch PLs1000
Moisture F2
Currently measured relative humidity at outdoor sensor (Rh)
dew point TP2
Calculated dew point on the outdoor sensor (degrees Celsius)
Absolute humidity 2
Calculated absolute humidity at outdoor sensor (g / m³)
dTP=TP1-TP2
determined difference of the dew points tP1 on the indoor sensor and tP2 on
the outdoor sensor
REL T1 timer
the switch-on delay ReL t1 time entered in the process can be viewed in this
menu item and shows the remaining time, from reaching the set setpoints, until
switching.
Interval ON
Remaining time (expiring) for the interval oN (switched on).
Interval OFF
Remaining time (expiring) for the interval oFF (switched off).
Settings (read only) ...
the settings can be checked without leaving the process „Interval Ventilation“.
to do this, select the bottom menu item
„Settings (read only) ...“
with the
Ok
button. With the help of the keys
,
you can call up and view the settings
made. Changes can only be made during the set-up menu. to return to the
set-up menu, press the
ESC
key.