SN6000 FC Switch #> zoning active
Active (enforced) ZoneSet Information
ZoneSet Zone ZoneMember
--------------------------------
wwn
wwn_b0241f
50:06:04:82:bf:d2:18:c2
50:06:04:82:bf:d2:18:d2
21:00:00:e0:8b:02:41:2f
wwn_23bd31
50:06:04:82:bf:d2:18:c2
50:06:04:82:bf:d2:18:d2
10:00:00:00:c9:23:bd:31
wwn_221416
50:06:04:82:bf:d2:18:c2
50:06:04:82:bf:d2:18:d2
10:00:00:00:c9:22:14:16
wwn_2215c3
50:06:04:82:bf:d2:18:c2
50:06:04:82:bf:d2:18:d2
10:00:00:00:c9:22:15:c3
To display the name of the active zone set and its activation history, enter the
zoneset active
command, as shown in the following example:
SN6000 FC Switch #> zoneset active
Active ZoneSet Information
--------------------------
ActiveZoneSet Bets
LastActivatedBy admin@OB-session6
LastActivatedOn day month date time year