HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 203
set config threshold
Description
Sets the port alarm threshold parameters by which the switch monitors port performance and
generates alarms. The changes you make with this command are not retained when you reset or
power-cycle the switch unless you save them using the
config save
command.
Authority
Admin session and a Config Edit session
Syntax
set config threshold
Initiates a configuration session by which to generate and log alarms for selected events. The system
displays each event, its triggers, and a sampling window one line at a time and prompts you for a
value. For each parameter, enter a new value or press
Enter
to accept the current value shown in
brackets.
Table 37
describes the port alarm threshold parameters.
Table 37
Port alarm threshold parameters
Parameter
Description
ThresholdMonitoringEnabled
Master enable/disable parameter for all events. Enables
(
True
) or disables (
False
) the generation of all
enabled event alarms. The default is
False
.
CRCErrorsMonitoringEnabled
DecodeErrorsMonitoringEnabled
ISLMonitoringEnabled
LoginMonitoringEnabled
LogoutMonitoringEnabled
LOSMonitoringEnabled
The event type enable/disable parameter. Enables
(
True
) or disables (
False
) the generation of alarms for
each of the following events:
•
CRC errors
•
Decode errors
•
ISL connection count
•
Device login errors
•
Device logout errors
•
Loss-of-signal errors
RisingTrigger
The event count above which a rising trigger alarm is
logged. The switch will not generate another rising
trigger alarm for that event until the count descends
below the falling trigger and again exceeds the rising
trigger.
FallingTrigger
The event count below which a falling trigger alarm is
logged. The switch will not generate another falling
trigger alarm for that event until the count exceeds the
rising trigger and descends again below the falling
trigger.
SampleWindow
The time in seconds in which to count events
Notes
The switch will down a port if an alarm condition is not cleared within three consecutive sampling
windows (by default, 30 seconds). Reset the port to bring it back online. An alarm is cleared when
the threshold monitoring detects that the error rate has fallen below the falling trigger.
Содержание StorageWorks SN6000
Страница 16: ...16 Command Line Interface Usage ...
Страница 20: ...20 User Account Configuration ...
Страница 34: ...34 Network Configuration ...
Страница 82: ...82 Zoning Configuration ...
Страница 86: ...86 Connection Security Configuration ...
Страница 96: ...96 Device Security Configuration ...
Страница 100: ...100 RADIUS Server Configuration ...
Страница 124: ...124 Simple Network Management Protocol Configuration ...
Страница 318: ...318 Command Reference ...
Страница 330: ...330 Index ...