228 Command Reference
The following is an example of the
set setup system timers
command:
SN6000 FC Switch (admin) #> set setup system timers
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current
value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Current Values:
AdminTimeout 30
InactivityTimeout 0
New Value (press ENTER to accept current value, 'q' to quit):
AdminTimeout (dec value 0-1440 minutes, 0=never) :
InactivityTimeout (dec value 0-1440 minutes, 0=never) :
Do you want to save and activate this system setup? (y/n): [n]
See also
show setup system
, page 271