HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide
45
Modifying a switch configuration
To modify a switch configuration, you must open an Admin session with the
admin start
command. The
Admin session prevents other accounts from making changes at the same time through Telnet, Simple SAN
Connection Manager, or any other management application. You must also open a Config Edit session
with the
config edit
command and indicate which configuration you want to modify. If you do not
specify a configuration name, the active configuration is assumed.
The Config Edit session provides access to the
set config
commands with which you make
modifications to the port, switch, port threshold alarm, or zoning configuration components, as shown in
the following example:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> config edit
The config named default is being edited.
SN6000 FC Switch (admin-config)#> set config port . . .
SN6000 FC Switch (admin-config)#> set config switch . . .
SN6000 FC Switch (admin-config)#> set config security . . .
SN6000 FC Switch (admin-config)#> set config threshold . . .
SN6000 FC Switch (admin-config)#> set config zoning . . .
The
config save
command saves the changes you made during the Config Edit session. In this case,
changes to the configuration named
Default
are being saved to a new configuration named
config_10132003
. However, the new configuration does not take effect until you activate it with the
config activate
command:
SN6000 FC Switch (admin-config)#> config save config_10132003
SN6000 FC Switch (admin)#> config activate config_10132003
SN6000 FC Switch (admin)#> admin end
The
admin end
command releases the Admin session for other administrators when you are finished
making changes to the switch. To make temporary changes to the switch administrative state, enter the
set switch state
command.
The following is an example of the
set config switch
command. See
Table 36
for descriptions of the
switch configuration parameters.
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> config edit
SN6000 FC Switch (admin-config) #> set config switch
A list of attributes with formatting and default values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
AdminState (1=Online, 2=Offline, 3=Diagnostics) [Online ]
BroadcastEnabled (True / False) [True ]
InbandEnabled (True / False) [True ]
FDMIEnabled (True / False) [True ]
FDMIEntries (decimal value, 0-1000) [1000 ]
DefaultDomainID (decimal value, 1-239) [2 ]
DomainIDLock (True / False) [False ]
SymbolicName (string, max=32 chars) [SN6000 FC Switch]
R_A_TOV (decimal value, 100-100000 msec) [10000 ]
E_D_TOV (decimal value, 10-20000 msec) [2000 ]
PrincipalPriority (decimal value, 1-255) [254 ]
ConfigDescription (string, max=64 chars) [Default Config]
Содержание StorageWorks SN6000
Страница 16: ...16 Command Line Interface Usage ...
Страница 20: ...20 User Account Configuration ...
Страница 34: ...34 Network Configuration ...
Страница 82: ...82 Zoning Configuration ...
Страница 86: ...86 Connection Security Configuration ...
Страница 96: ...96 Device Security Configuration ...
Страница 100: ...100 RADIUS Server Configuration ...
Страница 124: ...124 Simple Network Management Protocol Configuration ...
Страница 318: ...318 Command Reference ...
Страница 330: ...330 Index ...