38
Switch Configuration
System process information
The
ps
command displays system process information to help you determine what processes are running
and central processing unit (CPU) usage.
The column titles in the following example are:
•
PID—Process identifier
•
PPID—Parent process identifier
•
%CPU—Percentage CPU usage
•
%MEM—Percentage memory usage
•
TIME—Actual processing time
•
ELAPSED—Elapsed time since the process started
•
COMMAND—The command that initiated the process.
The following example displays current system processes.
SN6000 FC Switch #> ps
PID PPID %CPU %MEM TIME ELAPSED COMMAND
244 224 0.0 0.3 00:00:04 2-03:02:31 cns
245 224 0.0 0.3 00:00:06 2-03:02:31 ens
246 224 0.0 0.3 00:00:09 2-03:02:31 dlog
247 224 0.0 0.6 00:00:33 2-03:02:31 ds
248 224 0.3 2.8 00:09:59 2-03:02:31 mgmtApp
249 224 0.0 0.3 00:00:16 2-03:02:31 sys2swlog
251 224 0.0 0.4 00:00:06 2-03:02:30 fc2
252 224 0.0 0.6 00:00:16 2-03:02:30 nserver
253 224 0.0 0.8 00:00:08 2-03:02:30 PortApp
254 224 0.0 0.5 00:00:03 2-03:02:30 qfsApp
255 224 0.0 0.5 00:00:09 2-03:02:30 mserver
256 224 0.0 0.7 00:00:06 2-03:02:30 eport
257 224 0.0 0.6 00:00:13 2-03:02:30 zoning
282 254 0.0 0.5 00:00:00 2-03:02:26 qfsApp
284 224 0.0 0.6 00:00:08 2-03:02:26 snmpservicepath
285 282 0.0 0.5 00:00:00 2-03:02:26 qfsApp
308 224 0.0 0.8 00:00:29 2-03:02:25 cim_server
Elapsed time between resets
The
uptime
command displays the elapsed time since the switch was last reset and the reset method.
Note that a hot reset or non-disruptive firmware activation does not reset the elapsed time reported by this
command. The following example displays the time since the last reset.
SN6000 FC Switch #> uptime
Elapsed up time : 0 day(s), 2 hour(s), 28 min(s), 44 sec(s)
Reason last reset: NormalReset
Configuration information
The
show config
command displays a variety of configuration information at the port and switch levels.
In addition to the basic switch configurations, the
show config
command displays parameters that
control how data is maintained in the security and zoning databases. The
show config
command
displays the following types of information:
•
Switch configuration parameters
, page 39
•
Zoning configuration parameters
, page 39
•
Security configuration parameters
, page 40
See also ”
Displaying port information
” (page 57).
Содержание StorageWorks SN6000
Страница 16: ...16 Command Line Interface Usage ...
Страница 20: ...20 User Account Configuration ...
Страница 34: ...34 Network Configuration ...
Страница 82: ...82 Zoning Configuration ...
Страница 86: ...86 Connection Security Configuration ...
Страница 96: ...96 Device Security Configuration ...
Страница 100: ...100 RADIUS Server Configuration ...
Страница 124: ...124 Simple Network Management Protocol Configuration ...
Страница 318: ...318 Command Reference ...
Страница 330: ...330 Index ...