HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 245
show env
Description
Displays temperature and voltage information.
Authority
None
Syntax
show env
Examples
The following is an example of the
show env
command:
SN6000 FC Switch #? show env
Temperature(C) Sensors:
Sensor Description Status Current High Warn High Alarm
------ ----------- ------ ------- --------- ----------
0 BOARD Normal 24 65 70
1 DS1780 Normal 28 n/a n/a
2 MAX1617 Normal 31 65 70
3 ASIC Normal 49 95 100
Voltage Sensors:
Sensor Description Status Current Low Alarm High Alarm
------ ----------- ------ ------- --------- ----------
0 2.5V Good 2.50 2.20 2.80
1 1.25V Good 1.24 1.00 1.50
2 3.3V Good 3.32 3.02 3.58
3 12V Good 12.00 10.00 13.31
4 1.2V Good 1.26 1.04 1.38
5 1.5V Good 1.50 1.31 1.68
6 1.8V_ANALOG Good 1.78 1.58 2.02
7 1.8V Good 1.79 1.60 1.99
8 2.5V_ANALOG Good 2.40 2.08 2.84
See also
show temp
, page 277
show voltage
, page 284