HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 207
Table 40
Event display filter parameters
Parameter
Description
Critical
Critical severity-level events. The critical level describes events that are generally
disruptive to the administration or operation of the fabric, but require no action.
Warn
Warning severity-level events. The warning level describes events that are
generally not disruptive to the administration or operation of the fabric, but are
more important than the informative-level events.
Info
Informative severity-level events. The informative level describes routine events
associated with a normal fabric.
None
Specifies no severity levels for display on the screen
level [filter]
Specifies the severity level given by [filter] to use in monitoring and logging events for the
specified components or ports.
Table 41
describes the severity level monitoring parameters.
Table 41
Severity level monitoring parameters
Parameter
Description
Critical
Monitors critical events. The critical level describes events that are generally
disruptive to the administration or operation of the fabric, but require no action.
This is the default severity level.
Warn
Monitors warning and critical events. The warning level describes events that are
generally not disruptive to the administration or operation of the fabric, but are
more important than the informative level events.
Info
Monitors informative, warning, and critical events. The informative level describes
routine events associated with a normal fabric.
NOTE:
Logging events at the Info severity level can deplete switch
resources because of the high volume of events.
None
Monitors none of the severity levels
port [port_list]
Specifies one or more ports to monitor for events.
Table 42
describes the port monitoring
parameters.
Table 42
Port monitoring parameters
Parameter
Description
[port_list]
Specifies the port or ports to monitor. [port_list] can be a set of port numbers and
ranges delimited by spaces. For example,
0 2 10-15
specifies ports 0, 2, 10,
11, 12, 13, 14, and 15.
All
Specifies all ports
None
Disables monitoring on all ports
Содержание StorageWorks SN6000
Страница 16: ...16 Command Line Interface Usage ...
Страница 20: ...20 User Account Configuration ...
Страница 34: ...34 Network Configuration ...
Страница 82: ...82 Zoning Configuration ...
Страница 86: ...86 Connection Security Configuration ...
Страница 96: ...96 Device Security Configuration ...
Страница 100: ...100 RADIUS Server Configuration ...
Страница 124: ...124 Simple Network Management Protocol Configuration ...
Страница 318: ...318 Command Reference ...
Страница 330: ...330 Index ...