Hardware information
To display the status of the switch hardware, including fans, power supplies, internal temperature, and
Heartbeat LED status, enter the
show chassis
command.
The following is an example of the
show chassis
command:
SN6000 FC Switch #> show chassis
Chassis Information
-------------------
BoardTemp (1) - Degrees Celsius 26
BoardTemp (2) - Degrees Celsius 31
BoardTemp (3) - Degrees Celsius 31
PowerSupplyStatus (1) Good
HeartBeatCode 1
HeartBeatStatus Normal
The
HeartBeatCode
and
HeartBeatStatus
entries indicate the power-on self test (POST) results
revealed by the Heartbeat LED blink patterns. The result is normal operation or a blink pattern indicating a
critical error as described in
Table 3
. For information about Heartbeat LED blink patterns, see the
HP
StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide
.
Firmware information
To display a summary of switch identity information, including the firmware version, enter the
show version
command. The following is an example of the
show version
command:
SN6000 FC Switch #> show version
*****************************************************
* *
* Command Line Interface SHell (CLISH) *
* *
*****************************************************
SystemDescription HP StorageWorks SN6000 DualPower Supply Fibre
Channel Switch
HostName <undefined>
EthIPv4NetworkAddress 10.20.11.192
EthIPv6NetworkAddress ::
MACAddress 00:c0:dd:00:71:ee
WorldWideName 10:00:00:c0:dd:00:71:ed
ChassisSerialNumber FAM033100024
SymbolicName SN6000 FC Switch
ActiveSWVersion V8.0.x.x.xx.xx
ActiveTimestamp day month date time year
POSTStatus Passed
LicensedPorts 24
SwitchMode Full Fabric
Table 3
Heartbeat LED activity
HeartBeatCode–HeartBeatStatus
Description
1-Normal
One blink per second–Normal operation
2-AppDied
Two blink cluster–Internal firmware failure
3-PostFailed
Three blink cluster–Fatal POST error
4-CorruptFilesystem
Four blink cluster–Configuration file system error
5-Overheating
Five blink cluster– Over temperature
Содержание StorageWorks SN6000
Страница 16: ...16 Command Line Interface Usage ...
Страница 20: ...20 User Account Configuration ...
Страница 34: ...34 Network Configuration ...
Страница 82: ...82 Zoning Configuration ...
Страница 86: ...86 Connection Security Configuration ...
Страница 96: ...96 Device Security Configuration ...
Страница 100: ...100 RADIUS Server Configuration ...
Страница 124: ...124 Simple Network Management Protocol Configuration ...
Страница 318: ...318 Command Reference ...
Страница 330: ...330 Index ...