Configuring for Network Management Applications
Using SNMP Tools To Manage the Switch
5. Configure the target address of the SNMPv3 management station to which
SNMPv3 informs and traps are sent by entering the
snmpv3 targetaddress
command.
Syntax:
[no] snmpv3 targetaddress
< ipv4-addr
|
ipv6-addr> < name >
Configures the IPv4 or IPv6 address, name, and
configuration filename of the SNMPv3 management
station to which notification messages are sent.
params
< parms_name >
Name of the SNMPv3 station’s parameters file. The
parameters filename configured with
params
<params_name> must match the
params
<params_name> value entered with the
snmpv3 params
command in Step 6.
taglist <
tag_name
> [
tag_name
] ...
Specifies the SNMPv3 notifications (identified by one
or more <tag_name> values) to be sent to the IP address
of the SNMPv3 management station.
You can enter more than one <tag_name> value. Each
<tag_name> value must be already associated with the
name of an SNMPv3 notification configuration entered
with the
snmpv3 notify
command in Step 4.
Use a blank space to separate <tag_name> values.
You can enter up to 103 characters in <tag_name>
entries following the
taglist
keyword.
[filter < none | debug | all | not-info | critical>]
(Optional) Configures the type of messages sent to a
management station. Default:
none
.
[udp-port
< port >
]
(Optional) Specifies the UDP port to use
.
Default:
162
.
[port-mask
< mask >
]
(Optional) Specifies a range of UDP ports. Default:
0
.
[addr-mask
< mask >
]
(Optional) Specifies a range of IP addresses as
destinations for notification messages. Default:
0
.
[retries
< value >
]
(Optional) Number of times a notification is
retransmitted if no response is received. Range: 1-255.
Default:
3.
13-26
Содержание ProCurve 6120G/XG
Страница 1: ...ProCurve Series 6120 Switches Management and Configuration Guide November 2010 Version Z 14 22 ...
Страница 2: ......
Страница 3: ...HP ProCurve 6120G XG Switch 6120XG Switch November 2010 Z 14 22 Management and Configuration Guide ...
Страница 24: ...xxii ...
Страница 40: ...Getting Started To Set Up and Install the Switch in Your Network 1 10 ...
Страница 54: ...Selecting a Management Interface Advantages of Using ProCurve Manager or ProCurve Manager Plus 2 14 ...
Страница 70: ...Using the Menu Interface Where To Go From Here 3 16 ...
Страница 92: ...Using the ProCurve Web Browser Interface Contents Setting Fault Detection Policy 5 25 5 2 ...
Страница 160: ...Switch Memory and Configuration Automatic Configuration Update with DHCP Option 66 6 44 ...
Страница 288: ...Port Status and Configuration Uplink Failure Detection 10 42 ...
Страница 318: ...Port Trunking Outbound Traffic Distribution Across Trunked Links 11 30 ...
Страница 470: ...File Transfers Copying Diagnostic Data to a Remote Host USB Device PC or UNIX Workstation A 34 ...
Страница 487: ...Monitoring and Analyzing Switch Operation Status and Counters Data B 17 ...
Страница 518: ...Monitoring and Analyzing Switch Operation Traffic Mirroring B 48 ...
Страница 612: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Страница 616: ...Monitoring Resources When Insufficient Resources Are Available E 4 ...
Страница 620: ...Daylight Savings Time on ProCurve Switches F 4 ...
Страница 638: ...Network Out of Band Management OOBM Tasks G 18 ...
Страница 659: ...download to primary or secondary flash A 21 using to download switch software A 19 Index 19 ...
Страница 660: ...20 Index ...
Страница 661: ......