N o t e
Port Status and Configuration
Uni-Directional Link Detection (UDLD)
Syntax:
link-keepalive interval <
interval
>
Determines the time interval to send UDLD control packets. The
<interval> parameter specifies how often the ports send a UDLD
packet. You can specify from 10 – 100, in 100 ms increments,
where 10 is 1 second, 11 is 1.1 seconds, and so on.
Default: 50 (5 seconds)
Syntax:
link-keepalive retries <
num
>
Determines the maximum number of retries to send UDLD
control packets. The <num> parameter specifies the maximum
number of times the port will try the health check. You can specify
a value from 3 – 10.
Default: 5
Syntax:
[no] interface <
port-list
> link-keepalive vlan <
vid
>
Assigns a VLAN ID to a UDLD-enabled port for sending of tagged
UDLD control packets.Under default settings, untagged UDLD
packets can still be transmitted and received on tagged only
ports—however, a warning message will be logged.
The
no
form of the command disables UDLD on the specified
port(s).
Default: UDLD packets are untagged; tagged only ports will
transmit and receive untagged UDLD control packets
Enabling UDLD
UDLD is enabled on a per port basis. For example, to enable UDLD on port
a1, enter:
ProCurve(config)#interface al link-keepalive
To enable the feature on a trunk group, enter the appropriate port range. For
example:
ProCurve(config)#interface al-a4 link-keepalive
When at least one port is UDLD-enabled, the switch will forward out UDLD
packets that arrive on non-UDLD-configured ports out of all other non-UDLD
configured ports in the same vlan. That is, UDLD control packets will “pass
through” a port that is not configured for UDLD. However, UDLD packets will
be dropped on any blocked ports that are not configured for UDLD.
10-33
Содержание ProCurve 6120G/XG
Страница 1: ...ProCurve Series 6120 Switches Management and Configuration Guide November 2010 Version Z 14 22 ...
Страница 2: ......
Страница 3: ...HP ProCurve 6120G XG Switch 6120XG Switch November 2010 Z 14 22 Management and Configuration Guide ...
Страница 24: ...xxii ...
Страница 40: ...Getting Started To Set Up and Install the Switch in Your Network 1 10 ...
Страница 54: ...Selecting a Management Interface Advantages of Using ProCurve Manager or ProCurve Manager Plus 2 14 ...
Страница 70: ...Using the Menu Interface Where To Go From Here 3 16 ...
Страница 92: ...Using the ProCurve Web Browser Interface Contents Setting Fault Detection Policy 5 25 5 2 ...
Страница 160: ...Switch Memory and Configuration Automatic Configuration Update with DHCP Option 66 6 44 ...
Страница 288: ...Port Status and Configuration Uplink Failure Detection 10 42 ...
Страница 318: ...Port Trunking Outbound Traffic Distribution Across Trunked Links 11 30 ...
Страница 470: ...File Transfers Copying Diagnostic Data to a Remote Host USB Device PC or UNIX Workstation A 34 ...
Страница 487: ...Monitoring and Analyzing Switch Operation Status and Counters Data B 17 ...
Страница 518: ...Monitoring and Analyzing Switch Operation Traffic Mirroring B 48 ...
Страница 612: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Страница 616: ...Monitoring Resources When Insufficient Resources Are Available E 4 ...
Страница 620: ...Daylight Savings Time on ProCurve Switches F 4 ...
Страница 638: ...Network Out of Band Management OOBM Tasks G 18 ...
Страница 659: ...download to primary or secondary flash A 21 using to download switch software A 19 Index 19 ...
Страница 660: ...20 Index ...
Страница 661: ......