Port Status and Configuration
Viewing Port Status and Configuring Port Parameters
Specifies the port’s data transfer speed and mode. Does
not use the
no
form of the command. (
[
Default:
auto
.)
Note that in the above syntax you can substitute an “
int
” for “
interface
”; that
is:
int <
port-list
>
.
The 10/100 auto-negotiation feature allows a port to establish a link with a port
at the other end at either 10 Mbps or 100 Mbps, using the highest mutual speed
and duplex mode available. Only these speeds are allowed with this setting.
For example, to configure port C5 for auto-10-100, enter this command:
ProCurve(config)# int c5 speed-duplex auto-10-100
To configure ports C1 through C3 and port C6 for 100Mbps full-duplex, you
would enter these commands:
ProCurve(config)# int c1-c3,c6 speed-duplex 100-full
Similarly, to configure a single port with the above command settings, you
could either enter the same command with only the one port identified, or go
to the
context level
for that port and then enter the command. For example,
to enter the context level for port C6 and then configure that port for 100FDx:
ProCurve(config)# int e c6
ProCurve(eth-C6)# speed-duplex 100-full
If port C8 was disabled, and you wanted to enable it and configure it for
100FDx with flow-control active, you could do so with either of the following
command sets.
These commands enable and configure
port C8 from the config level:
ProCurve(config)# int c8 enable
ProCurve(config)# int c8 speed-duplex 100-full
ProCurve(config)# int c8 flow-control
ProCurve(config)# int c8
ProCurve(eth-C8)# enable
ProCurve(eth-C8)# speed-duplex 100-full
These commands select the port C8
context level and then apply the
subsequent configuration commands to
port C8:
Figure 10-9. Examples of Two Methods for Changing a Port Configuration
Refer to “Enabling or Disabling Flow Control” on page 10-17 for more on flow
control.
10-16
Содержание ProCurve 6120G/XG
Страница 1: ...ProCurve Series 6120 Switches Management and Configuration Guide November 2010 Version Z 14 22 ...
Страница 2: ......
Страница 3: ...HP ProCurve 6120G XG Switch 6120XG Switch November 2010 Z 14 22 Management and Configuration Guide ...
Страница 24: ...xxii ...
Страница 40: ...Getting Started To Set Up and Install the Switch in Your Network 1 10 ...
Страница 54: ...Selecting a Management Interface Advantages of Using ProCurve Manager or ProCurve Manager Plus 2 14 ...
Страница 70: ...Using the Menu Interface Where To Go From Here 3 16 ...
Страница 92: ...Using the ProCurve Web Browser Interface Contents Setting Fault Detection Policy 5 25 5 2 ...
Страница 160: ...Switch Memory and Configuration Automatic Configuration Update with DHCP Option 66 6 44 ...
Страница 288: ...Port Status and Configuration Uplink Failure Detection 10 42 ...
Страница 318: ...Port Trunking Outbound Traffic Distribution Across Trunked Links 11 30 ...
Страница 470: ...File Transfers Copying Diagnostic Data to a Remote Host USB Device PC or UNIX Workstation A 34 ...
Страница 487: ...Monitoring and Analyzing Switch Operation Status and Counters Data B 17 ...
Страница 518: ...Monitoring and Analyzing Switch Operation Traffic Mirroring B 48 ...
Страница 612: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Страница 616: ...Monitoring Resources When Insufficient Resources Are Available E 4 ...
Страница 620: ...Daylight Savings Time on ProCurve Switches F 4 ...
Страница 638: ...Network Out of Band Management OOBM Tasks G 18 ...
Страница 659: ...download to primary or secondary flash A 21 using to download switch software A 19 Index 19 ...
Страница 660: ...20 Index ...
Страница 661: ......