Table 56 Contents of the Copy Group Attributes Panel
(continued)
When effective
Copy type
Description
Item
When the
YKMAKE
command is executed.
3
CAJ
Specify the journal group number
of the secondary site as a sub C/T
group ID (required)
Specify a value between
OO
and
FF
.
NOTE:
For configurations that use
delta resync, specify the same value
for both the UR copy pair and the
UR copy pair for delta resync.
sub C/T ID (JNLG)
When the
YKMAKE
command is executed.
1
CAJ
Specify the Mirror ID in the range
from 0 to 3 (required for CAJ).
4
MIRROR ID
•
When the YKMAKE
command is executed
•
When the YKRESYNC
command is executed
CA
Specify the fence level (required for
CA).
•
DATA
: Places P-VOL in fence
status (updates suppressed) when
updates in P-VOL cannot be
copied to S-VOL due to a
problem such as a failure.
•
STATUS
: Places P-VOL in fence
status (updates suppressed) when
updates in P-VOL cannot be
copied to S-VOL due to a
problem such as a failure. If the
operation from the primary site
attains the suspend status,
updates to P-VOL are accepted.
•
NEVER
: P-VOL is never in fence
status (updates suppressed).
When a copy pair is suspended,
updates to P-VOL are accepted.
NOTE:
•
FENCE LVL cannot be altered
when a C/T group ID is
specified.
•
For the system volume that is
used for control by the OS or
applications such as Business
Continuity Manager, specify
DATA
or
STATUS
for
FENCE LVL
to create a copy pair and
operate the system. Write to
P-VOL is prohibited and the OS
or application might hang when
a failure problem occurs. For that
reason, if you use the system
volume as a CA copy pair,
specify
NEVER
for
FENCE LVL
or
set the system volume itself not
to CA copy the pair.
FENCE LVL
When the
YKMAKE
command is executed
3
CA
Specify whether to freeze a storage
system (place in SCP status) when
a failure suspension (SUSPER)
occurs.
•
Y
: Place in SCP status.
5
•
N
: Do not place in SCP status.
FREEZE SCP