Figure 65 Copy Group Detail Definition Panel
“Items in the Copy Group Detail Definition panel” (page 74)
describes the items in the Copy Group
Detail Definition panel. Note that changes for each item will be applied to the storage system
settings when the copy pair is reloaded (by executing the YKLOAD command) and then created.
For Continuous Access Synchronous for Mainframe copy pairs with the HyperSwap attribute,
because Business Continuity Manager cannot perform copy pair operations, if you change the
definitions of the items that require the
YKMAKE
command to make changes, the changes will not
be applied to the storage system settings.
Table 54 Items in the Copy Group Detail Definition panel
When effective
Description
Item
When the
YKMAKE
command is executed
1
Copy type of the copy group
Copy Group Type
N/A
Copy group ID
Copy Group ID
N/A
Primary DAD ID
Primary Device Address
Domain
N/A
Secondary DAD ID
Secondary Device Address
Domain
When the
YKMAKE
command is executed
1
.
Specify / to define an EXCTG attribute.
2
This is only effective when the copy type is CAJ; if the copy
type is other than CAJ, an error message is displayed.
Enable EXCTG Attributes
When the
YKMAKE
command is executed.
Unless all volumes are
SIMPLEX, execution
might not be executed
properly.
1
Specify an EXCTG ID (0 to 3) for copying in the forward
direction.
EXCTG ID (Forward)
When the
YKMAKE
command is executed.
1
Specify an EXCTG ID (0 to 3) for copying in the reverse
direction.
EXCTG ID (Reverse)
When the
YKMAKE
command is executed.
1
Select to define a container.
This check box cannot be cleared if there are multiple copy
groups.
Use Container
74
ISPF Panels