1
Information for the physical DKC serial number can be obtained when Business Continuity Manager 5.2 or later scans
a device.
2
Information for the logical DKC serial number can be obtained when Business Continuity Manager 5.2 or later scans
a device.
When Business Continuity Manager scans a device that exists in either of the following models, a value of
0
is set:
•
HP StorageWorks XP12000/XP10000 Disk Array
•
HP StorageWorks XP24000/XP20000 Disk Array
•
HP StorageWorks P9500 Disk Array
A value of
0
is also set when the
YKLOAD
command is executed.
External volume information can be obtained when Business Continuity Manager 4.1 or later scans an HP StorageWorks
XP12000/XP10000 Disk Array. If information cannot be obtained, the value is null.
3
Created for each CU, thus the device information is created for each defined CU (CU number). The xx in
CU
xx is a
CU number (hexadecimal value).
Example of CUxx:
If
C400
is set to SSID of CU=05, the value for
CU05.SSID
is
C400
.
4
Created for each CCA, thus the device information is created for each defined CCA (CCA number). The xx in
CCA
xx
is a CCA (hexadecimal value).
Example of CCAxx:
If
STRG01
is set to the volume serial number of CCA=FF within CU=05, the value for
CU05.CCAFF.Volser
is
STRG01
.
5
External volume information can be obtained when Business Continuity Manager 4.1 or later scans a device that exists
in either of the following disk array models. If information cannot be obtained, the value is null.
•
HP StorageWorks XP12000/XP10000 Disk Array
•
HP StorageWorks XP24000/XP20000 Disk Array
Route List Structure
Table 149 (page 335)
shows the route list structure. The prefix for the name of the route list structure
is
HCC.ROUTELIST.
dad-id.
NOTE:
You can use the
YKDROP
command to drop the REXX variables in any route list structure
that was loaded by using the
YKLOAD
command.
Each REXX variable is preceded by a period (
.
).
Table 149 Route List Structure
Description
REXX variables
Last update ID
ID
Route list ID
ID
APID
APID
Unique IF# given to local host (0x
00
-
1F
)
IF#
First cylinder (fixed value of
0001
)
CYL
First track (fixed value of
00
)
HD
Slot size of dummy dataset (fixed value of
2000
)
SLOTSIZE
Number of Routes
0
Route priority (fixed value of
1
)
Priority
n
1
Number of the storage system used as route entry
0
Storage system serial number used as route entry
SerialNum
n
2
DAD ID to which a command device belongs
DADID
About REXX Variable Structures 335
Содержание P9000