Table 81 Contents of the Volume Query Information (CA) Panel
(continued)
Description
Item
•
For Primary: Device number for P-VOL of
the copy pair specified in the Copy Group
Pair Status panel
•
For Secondary: Device number for S-VOL
of the copy pair specified in the Copy
Group Pair Status panel
The following volume online information is
displayed to the right of
DEVN
:
1
•
*
: Online
•
-
: Offline
Nothing is displayed when volume online
information cannot be obtained.
DEVN
Copy pair status
7, 2
Status
Copy direction in the copy pair
Dir
Storage system serial number of the volume
which makes a copy pair
SN
Pair Volume
SSID for the volume which makes a copy pair
SSID
CU number of the volume which makes a copy
pair
CU
CCA of the volume which makes a copy pair
CCA
Device number of the volume which makes a
copy pair
DEVN
1
It is not displayed when the
YKQRYDEV
command has been executed for the HP StorageWorks XP1024/XP128 Disk
Array.
2
For details about the status of the displayed copy pair, see the table (for CA/CAA) that shows the copy pair statuses
of volumes obtained by using the
YKQRYDEV
command, in the HP StorageWorks P9000 for Business Continuity
Manager Software Users Guide. Note that when the device is a command device of either of the following models,
CDEV(
apid
)
is displayed in the
Status
column (apid: APID):
•
HP StorageWorks XP12000/XP10000 Disk Array
•
HP StorageWorks XP24000/XP20000 Disk Array
•
HP StorageWorks P9500 Disk Array
3
If the emulation type of the journal volume is OPEN,
JOURNAL
is not displayed.
4
This value is invalid for CA copy pairs with the HyperSwap attribute.
5
The timing for when the defined values are reflected is as shown in
“Contents of the Copy Group Attributes Panel”
(page 79)
, in the table item of When effective.
6
It is displayed if P-VOL or S-VOL is shared with other copy pairs in the definition (for example, in a 1:n BC copy pair
configuration or when S-VOL for CAA is used as P-VOL for BC).
7
MISMATCH
might be displayed. This happens when the device information during definition, as indicated by
Primary
Volume
and
Secondary Volume
, differs from the device information reported by the storage system. In this case, the
device information reported by the storage system is displayed in the
Pair Volume
column. If
MISMATCH
is displayed,
check the configuration file used, as well as the actual storage system configuration information and settings.
144 ISPF Panels