Table 83 Contents of the Volume Query Information (CAJ) Panel
(continued)
Description
Item
CCA of the volume that
makes a copy pair
CCA
Device number of the volume
that makes a copy pair
DEVN
1
Displayed if P-VOL or S-VOL is shared with other copy pairs in the definition (for example, in a
1
:n BC copy pair configuration or when S-VOL for CAA is used as P-VOL for BC).
2
MISMATCH
might be displayed. This happens when the device information at definition, as
indicated by
Primary Volume
and
Secondary Volume
, differs from the device information reported
by the storage system. In this case, the device information reported by the storage system is
displayed in the
Pair Volume
column. If
MISMATCH
is displayed, check the configuration file used,
as well as the actual storage system configuration information settings.
3
The timing for when the defined values are reflected is as described in
Table 56 (page 79)
, in
the table item of When effective.
4
Not displayed when the command has been executed for the HP StorageWorks XP1024/XP128
Disk Array.
5
For details about the status of the displayed copy pair, see the table (for CAJ) that shows the
copy pair statuses of volumes obtained by using the
YKQRYDEV
command, in the HP StorageWorks
P9000 for Business Continuity Manager Software Users Guide. Note that when the device is a
command device of either of the following models,
CDEV(
apid
)
is displayed in the
Status
column
(apid: APID):
•
HP StorageWorks XP12000/XP10000 Disk Array
•
HP StorageWorks XP24000/XP20000 Disk Array
•
HP StorageWorks P9500 Disk Array
6
If the emulation type of the journal volume is OPEN,
JOURNAL
is not displayed.
7
The following format shows the registration status of the restore journal group of the CAJ copy
pair in EXCTG:
status1(flag1,flag2) - status2(flag3,flag4), where:
status1: Indicates whether the journal group of the copy destination volume has
been registered in a storage system as EXCTG when a copy is being performed in
the forward direction. The characters displayed in status1 are determined according
to the values for flag1 and flag2 and status1 may have one of the following values:
•
active
: The journal group has been registered in a storage system as EXCTG.
This copy pair is ready to be used by 4x4 CAJ in the forward direction.
•
inactive
: The journal group has not been registered, a registration error
occurred or the user added information later. This copy pair is not ready to be
used by 4x4 CAJ in the forward direction.
•
invalid
: Invalid status
•
N/A
: Unable to identify the status.
flag1: Indicates, by using a flag, whether the journal group of the copy destination
volume has been registered in a storage system as EXCTG when a copy is being
156
ISPF Panels
Содержание P9000
Страница 302: ...YKDEMO12 302 CLI Commands ...