text-2 ~ <string of 70 or fewer characters>
Use this parameter when you want to output a multi-line message. For this parameter, specify the
second line of the text that you want to output.
text-3 through text-10 ~ <string of 70 or fewer characters>
Use these parameters when you want to output more than two lines for a message. The specification
method is the same as for the text-2 parameter.
NOTE:
For a multiline message, the message text can be output to a maximum of 10 lines.
Return codes
Table 140 (page 263)
lists the return codes to be returned when the YKWTOMSG command
terminates.
Table 140 YKWTOMSG Command Return Code List
Meaning
Return code
The command completed normally.
0
No type has been specified.
1004
The specified type is invalid.
1008
No text has been specified.
1012
The specified text is invalid.
1016
A system error occurred.
2000
Refer to the return code of the
WTO
macro. For details, see the IBM documentation MVS
Programming: Assembler Services Reference.
Other than above
CLI Command Coding Examples
Coding examples for each CLI command are stored in the sample library HPQYSAMT as sample
scripts.
Table 141 (page 263)
lists the sample scripts stored in
HPQYSAMT
.
Table 141 List of Sample Scripts
Overview
Sample script name
Uses the following CLI commands to demonstrate basic operations on copy
groups:
•
YKLOAD
•
YKMAKE
•
YKSUSPND
•
YKRESYNC
•
YKDELETE
•
YKQUERY
•
YKEWAIT
YKDEMO01
Uses the following CLI commands to demonstrate FlashCopy linkage:
•
YKFCSTAT
•
YKSLEEP
YKDEMO02
Command details 263
Содержание P9000
Страница 302: ...YKDEMO12 302 CLI Commands ...