Overview of Server Installation
3.
After marking the front of the rack, flip the template over, then repeat the
procedure on the back rails of the rack. Also mark the top of the template on the
rack to help align the next components.
Inserting Cage Nuts into the Rack Frame
Use the fitting tool to insert cage nuts on the
inside
of the rails at the marked
locations. Make sure to install two cage nuts at the front of the rack. These will be
used to secure the server chassis to the rack using the two front panel thumbscrews
(refer to Figure 2-15).
NOTE:
The cage nuts and fitting tool are included in the hardware kit supplied with the rack.
1.
On the inside of the rail, hook one of the lips of the cage nut through the square
rail hole.
2.
Insert the tip of the fitting tool through the other side of the hole, then hook the
opposite lip of the cage nut.
Figure 2-8: Inserting cage nuts into the rack frame
3.
Using the fitting tool as a lever, slide the cage nut lip into position.
4.
Repeat this procedure for each cage nut.