Hardware Options Installation
3-50
HP ProLiant ML350 Generation 3 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Richard O. Heath File Name: d-ch3 Hardware Options Installation.doc
Codename: Steel Venom Part Number: 316354-001 Last Saved On: 12/6/02 3:06 PM
1.
Identify the redundant power supply bay at the back of the server.
IMPORTANT:
Power supplies of these servers are hot-pluggable. When using the redundant
power supply option, it is not necessary to power down the server before removing or installing
a power supply.
Figure 3-43: Identifying the redundant power supply bay
2.
Remove the thumbscrew that secures the redundant power supply blank, and then
lift the blank from the back of the server.
WARNING: To reduce the risk of electric shock or damage to the equipment,
do not connect AC power cords to uninstalled power supplies.
3.
Slide the power supply into the power supply bay, then apply pressure to the
power supply until the release/lock lever clicks the power supply securely into
the bay.
4.
Connect the AC power cord to the power supply.
5.
Be sure that the power supply and the redundant power supply LEDs are green.
For more information, refer to Appendix E, “LED Indicators, Switches, and
Jumpers.”